https://www.phoenixcontact.com/ie/products/1020775
Connector - PV-C4M-S 2,5-6 (-) - 1020775
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Photovoltaic connector, Range of articles: PV-C4M-S, Connector, housing material: PPE, color: black, min.
conductor cross section: 2.5 mm², max. conductor cross section: 6 mm², rated current: 20 A, Connection
method: Spring-cage, Type of contact: Pin
Key Commercial Data
Packing unit
50 pc
Minimum order quantity
50 pc
GTIN
GTIN
4055626511283
Weight per Piece (excluding packing)
19.600 g
Technical data
Dimensions
External cable diameter
5 mm ... 8 mm
Ambient conditions
Degree of protection (when plugged in)
IP66 / IP68 (2 m / 24 h)
Ambient temperature (operation)
-40 °C ... 85 °C
Ambient temperature (assembly)
-25 °C ... 50 °C
General
Design
Pin
Tightening torque nut
2 Nm ±0.1 Nm
Insertion force
45 N ±10 N
Disconnect force
250 N ±50 N (when locked)
Pull-out force of cable >= disconnect force
> 80 N
Insertion/withdrawal cycles
100
Degree of pollution
2
Degree of protection
IP66 / IP68 (2 m / 24 h)
03/05/2021 Page 1 / 4
https://www.phoenixcontact.com/ie/products/1020775
Connector - PV-C4M-S 2,5-6 (-) - 1020775
Technical data
General
Voltage
1500 V
Current
35 A
Rated surge voltage (III/3)
16 kV
pluggable
Yes
Nominal cross section
6 mm²
Protection class
II
Material
Color
black
Insulating material
mPPE
Contact material
Cu
Contact surface material
Ag
Connection data
Connection method
Spring-cage
Connection capacity
2.5 mm² ... 6 mm²
Contact resistance with connected conductor
0.45 mΩ
Stripping length
15 mm
Cable type
H1Z2Z2-K cable
Type of contact
Pin
Standards and Regulations
Flammability rating according to UL 94
V0
Safety note
• WARNING: Commission properly functioning products only. The
products must be regularly inspected for damage. Decommission
defective products immediately. Replace damaged products. Repairs
are not possible.
• WARNING: Only electrically qualified personnel may install and
operate the product. They must observe the following safety notes.
The qualified personnel must be familiar with the basics of electrical
engineering. They must be able to recognize and prevent danger. The
relevant symbol on the packaging indicates that only personnel familiar
with electrical engineering are allowed to install and operate the product.
WARNING: The connectors may not be plugged in or disconnected
under load. Ignoring the warning or improper use may damage persons
and/or property.
• The products are suitable for applications in plant, controller, and
electrical device engineering.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data
of the standards listed (e.g. the ones listed in the product accessories
online at phoenixcontact.com/products).
• When using the product in direct connection with third-party
manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must
be grounded
• Ensure that the protective or functional ground has been properly
connected.
03/05/2021 Page 2 / 4
https://www.phoenixcontact.com/ie/products/1020775
Connector - PV-C4M-S 2,5-6 (-) - 1020775
Technical data
Standards and Regulations
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• The installation notes/Design In documents online on the download
page at phoenixcontact.com/products must be observed for this product.
• Use a protective cap to protect connectors that are not in use. The
suitable accessories are available online in the accessory section of the
product at phoenixcontact.com/products
• The connector warms up in normal operation. Depending on the
ambient conditions, the surface of the connector can continue to warm
up. In this case, the user is responsible for posting warnings (e.g. DIN
EN ISO 13732-1:2008-12).
• Operate the connector only when it is fully plugged in and interlocked.
• Ensure that when laying the cable, the tensile load on the connectors
does not exceed the upper limit specified in the standards.
• Observe the minimum bending radius of the cable. Lay the cable
without twisting it.
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Dimensional drawing
82,6
27,4
Ø20
15
16
Classifications
eCl@ss
eCl@ss 10.0.1
27440102
eCl@ss 11.0
27440102
eCl@ss 9.0
27440102
Accessories
Accessories
Photovoltaic connector
03/05/2021 Page 3 / 4
https://www.phoenixcontact.com/ie/products/1020775
Connector - PV-C4M-S 2,5-6 (-) - 1020775
Accessories
Protective cap - PV-C PROTECTION CAP - 1785430
Photovoltaic connector, Range of articles: SUNCLIX, Protective cap, color: black. self-sealing, without interlock, set
consisting of: 1 protective cap for connector side and 1 protective cap for coupling side
Filler plugs - PV-C-PLUG-HV - 1623478
Photovoltaic connector, Filler plugs, housing material: PA 6
Screwdriver tools
Screwdriver - SZF 1-0,6X3,5 - 1204517
Actuation tool, for ST terminal blocks, also suitable for use as a bladed screwdriver, size: 0.6 x 3.5 x 100 mm, 2component grip, with non-slip grip
Stripping tool
Stripping pliers - QUICK WIREFOX 6 SC - 1207637
Stripping tool for short-circuit proof conductors, stripping range: 1.5 up to 6 mm², wire cutting up to 6 mm² cable
stopper up to 18 mm²
Stripping tool - WIREFOX-D SR 6-1 - 1212511
Stripping tool, for standard 2.5, 4, and 6 mm² solar cables, with 15 mm length stop, for SUNCLIX field connectors
Phoenix Contact 2021 © - all rights reserved
http://www.phoenixcontact.com
03/05/2021 Page 4 / 4
很抱歉,暂时无法提供与“PV-C4M-S 2,5-6 (-)”相匹配的价格&库存,您可以联系我们找货
免费人工找货